10 KOMPLEXER Manual EN
MIDI controller
To allocate a parameter to a certain MIDI Continuous Controller (MIDI CC), click the fader
while holding down ALT. The MIDI controller window then opens. Click the number field to
enter a number directly using the computer keyboard or move
an operating element on your hardware controller. If the
controller outputs a MIDI CC, the number automatically
appears in the allocation window (learn function). Click OK to
accept the change. If the same MIDI CC has previously been
allocated to another parameter, this allocation is removed or assigned the value OFF.
MIDI CC number 0 cannot be used. If you enter 0 as the MIDI CC number, the controller
allocation for this parameter is disabled.
Some parameters are assigned fixed MIDI controller numbers. This is for better support of
the KOMPLEXER DSP module, which will be available soon. Therefore, these MIDI CC
numbers are not available for other parameters. The following parameters have fixed
allocations:
Parameter MIDI CC No.
Volume 7
MACRO controller [Expression] 11
MACRO controller [Character] 6
MACRO controller [Warp] 8
MACRO controller [Effect] 9
MACRO controller [Attack] 3
MACRO controller [Decay] 62
MACRO controller [Sustain] 63
MACRO controller [Release] 119
Effect 1 MIX 91
Effect 2 MIX 19